YF 3010E620 Series Electric Fuel Metering Unit
The Young & Franklin 3010E620 Valve is electro-mechanically actuated (EMA) and provides unchoked flow for use on aeroderivative turbines. This FMU is certified for use in hazardous locations around the world.
Flow Profile | Non-linear | ||||||||
Effective Area |
.93 in2 (600 mm2 ) | ||||||||
Estimated Dry Weight |
90 lbs. (41 kg)
|
||||||||
Slew Time |
≤200 ms
|
||||||||
Trip Time |
≤250 ms
|
||||||||
Maximum Operating Pressure |
1440 psig (99 barg) @ -20° to 100°F (-29° to 38°C)
1150 psig (79 barg) up to 400°F (204°C) |
||||||||
Burst Pressure |
5x Maximum Operating Pressure
|
||||||||
Valve Flange Size |
ASME B 16.5 Class 600 Flange
|
||||||||
Fluid Temperature Range |
-0°F to 400°F (-18°C to 204°C)
|
||||||||
Ambient Temperature Range |
-4°F to 212°F (-20°C to 100°C)
|
||||||||
Mean Time Between Service |
96,000 Hours
|
||||||||
Mean Time Between Failures (MTBF) |
290,000 Hours
|
||||||||
Valve Materials |
Stainless Steel (NACE MRO175 Compliant)
|
||||||||
Bandwidth/Frequency Response |
Customizable up to 23 Hz with 3dB attentuation
|
||||||||
Independent Feedback |
2 LVDTs (Optional)
|
||||||||
Motor Coil |
Class F insulation (311°F, 155°C)
|
||||||||
LVDT Wiring |
6.56 ft (2 m) Flying Lead or MIL Connector
|
||||||||
Motor Wiring |
3 ft (.91 m) Flying Lead or 32.8 ft (10 m) Jacketed Cable
|
||||||||
Visual Position Indicator |
Yes
|
||||||||
Ingress Protection |
IP65
|
||||||||
Seat Leakage |
Class IV per ANSI FCI 70-2
|
||||||||
Stem Leakage |
Zero Leakage, as shipped
|
||||||||
Failure Mode |
Spring to drive valve to Safe position (Fail Close)
|
||||||||
Environmental |
MIL-STD-810 - Shock and Vibration
|
||||||||
Command |
4-20 mA Position, -8 to +8 mA Triple Redundant Velocity
|
||||||||
Certifications |
Standard Assembly: Class 1 Div 2, Group B, C & D, T3 Ex db IIB+H2 T3 Gb
With Optional LVDTs: Class 1 Div 2, Group B, C & D, T3 Ex db ib IIB+H2 T3 Gb
|
Attachment | Size |
---|---|